Sydney Children Hospital, Randwick, New South Wales.

Leisure Centre at 70-74 Central Avenue, Oran Park, NSW 2570

Puggle-SYD 701 at 10 Eastern Creek Dr, Eastern Creek, NSW

SYD700 at Lot 4331 Bluett Drive, Smeaton Grange, NSW

Pioneer Drive and New Lakes Entrance Road, Oak Flats, NSW 2529

24 The Strand, Whale Beach, NSW

GDA was engaged by the earthwork contractor to design Cantilever, Anchored contiguous pile wall for approx. 464m of wall as well as 3 crane bases piles and foundation piles on the adjacent road. GDA have used latest state of the art software packages to design the retention wall and foundation piles. GDA also provided drawings and full drafting services.

GDA was engaged by the piling contractor to design and certify 294 nos of 450-1050mm diameter piles. As part of GDA scope, we carried out 6 PDA tests on production piles to justify the geotechnical parameters assumed in the detail design. Tests results were satisfactory and a useful tool to reduce time and cost for the client as well as helping environment using less materials

GDA designed and certified 35 no of 450-600mm dia foundation piles for this project

GDA designed and certified 35 no of 450mm dia foundation piles for this project

GDA designed and certified 50 no of 450-600mm dia foundation piles for this project

GDA was engaged by the piling contractor to design Cantilever contiguous piles wall as well foundation piles on this project. During the course of the design GDA had to liaise with the client and structural engineer in depth to understand the need of the project and design the contiguous wall according using well know software in Australian market.

Design More Efficient-More Sustainable Future

Our vision is providing the most efficient and sustainable solution to our clients with:

Our Design Services

Deep Foundations

Bored Piles

Continuous Flight Auger Piles (CFA)

Displacement Piles

Tower Crane base piles

Barrettes

Retaining Structures

Soldier piles and infill shotcrete panels

Contiguous piles

Secant pile wall & Cased Secant pile wall

Diaphragm wall

Sheet pile/Combi wall

Cutter Soil mixing wall

Pile Testing

Pile Integrity Testing (PIT)

Cross Hole Sonic testing (CHS)

Pile Dynamic Testing (PDA)

Risk Assessment & Method Statements for Piling Works

Having years of experience in piling companies, GDA can assist you in providing risk assessment and method statements for your piling projects

Forensic Assessment of Geotechnical and Piling Problems

If as Client, Contractor or Sub-Contractor, you believe you have incurred loss and expense on your foundation engineering project for reasons that you believe are not your own, GDA can investigate and advise you on the reasons why the loss has been incurred. Our reports are factual and without bias because our commitment is to provide you with the best advice possible even if the answer you get is not the one you had hoped for. We believe that the unvarnished truth is always the best advice you can receive.